Prefabrication of
steel-concrete composite decks can improve their competitiveness and
sustainability. This paper presents recent studies of longitudinal shear
connection at the University of Belgrade, Faculty of Civil Engineering. Grouped
welded headed studs and bolted shear connectors, suitable for prefabricated
composite construction, has been examined in push-out tests. Totally 30 tests
were conducted, and advanced FEA were made using Abaqus/Explicit dynamic
solver. Based on the experimental and numerical studies behaviour those two
shear connectors are compared.
Dedic DJ, Klaiber
WF. High-Strength Bolts as Shear Connectors in Rehabilitation Work. Concrete
international 1984;6(7):41-46.
EN1994-1-1:
Eurocode 4 - Design of composite steel and concrete structures. Part 1-1:
General rules and rules for buildings. Brussels, Belgium: European Committee
for Standardization (CEN); 2004.
EN1994-2: Eurocode
4 - Design of Composite Steel and Concrete Structures. General Rules and Rules
for Bridges. Brussels, Belgium: European Committee for Standardization (CEN);
2005.
Hawkins N. Strength
in shear and tension of cast- in-place anchor bolts. Anchorage to Concrete
1987;SP-103:233-255.
Kwon G.
Strengthening existing steel bridge girders by the use of post-installed shear
connectors. PhD thesis. The University of Texas at Austin, 2008:p.239.
behaviour with
deconstructable bolted shear connectors. Proceedings of the 2013 Composite Construction
in Steel and Concrete VII.
Marshall WT, Nelson
HM, Banarjee HK. An experimental study of the use of high strength fric-
tion-grip bolts as shear connectors in composite beams. The Structural Engineer
1971;49(4):171- 178.
Okada J, Teruhiko Y
Lebet JP., A study of the grouped arrangements of
stud connectors on shear strength behaviour, Structural Eng./Earthquake
Eng.,JSCE 2006;23(1):75-89.
Pavlovic M,
Markovic Z, Veljkovic M, Budjevac D, Bolted shear connectors vs. headed studs
behaviour in push-out tests, Journal of Constructional Steel Research
2013;88:134-149.
Pavlovic M.,
Resistance of bolted shear connectors in
prefabricated steel-concrete composite decks, PhD thesis, University of
Belgrade, Faculty of Civil Engineering; 2013.
Sedlacek G.
Hoffmeister B. Trumpf H. Kuhn B. et al. Composite bridge design for small and medium spans. Final
report. European Commission - technical steel research Contract No 7210-
PR/0113. Luxembourg, 2003.
Shim CS,
Lee, PG, Kim DW, Chung CH., Effects of Group
Arrangement on the Ultimate Strength of Stud Shear Connection. Proceedings of
the 2008 Composite Construction in Steel and Concrete Conference VI, ASCE Conf.
Proc.
Spremic M, Markovic
Z, Veljkovic M, Budjevac D., Push-out experiments of headed shear studs
in group arrangements, Advanced Steel Construction;
2013,9(2):170-191.
Spremic M., The analysis of headed studs group behavior in composite steel-concrete
beam, PhD thesis, University of Belgrade, Faculty of Civil Engineering; 2013.